Ask the Community
Groups
Setting a Traverse service to restart automatically on failure - Connect IT Community | Kaseya
<main> <article class="userContent"> <p><strong>PROBLEM</strong></p> <p>A traverse component may encounter a fatal error and the component may terminate. In such cases, it is desirable to have the component restatr automatically so as to minimize impact</p> <p> </p> <p><strong>CAUSE</strong></p> <p>The component may encounter any number of issues, such as for example, an out of memory (OOM) condition.</p> <p><br><strong><br>RESOLUTION </strong></p> <p>The service must be set to start up on failure if it is not already configured to do so.</p> <p> </p> <p><strong>Steps:</strong><br>The example listed here is that of the Traverse 'BVE API' component</p> <p>* Launch services.mmc<br>* Find and select the service, in this case 'Traverse BVE API'<br>* Right click and select Properties<br>* In the properties message box, click on the Recovery tab<br>* Set each of 'First failure'. 'Second failure' and 'Subsequent failures' to the value 'Restart the Service'</p> <p> </p> <p><strong>APPLIES TO</strong><br>All Traverse Windows installation</p> <p> </p> <p><strong>REFERENCE </strong></p> <p><strong>-</strong></p> <p> </p> </article> </main>