CVE-2015-5352 openssh: XSECURITY restrictions bypass under certain conditions in ssh(1)
CVE ID CVE-2015-5352 DESCRIPTION It was found that the OpenSSH client did not properly enforce the ForwardX11Timeout setting. A malicious or compromised remote X application could possibly use this flaw to establish a trusted connection to the local X server, even if only untrusted X11 forwarding was requested. RESOLUTION…
-
Red LED on the front of my Unitrends appliance is lit - diagnosing it with IPMI
SUMMARY Red LED on the front of my Unitrends appliance is lit - diagnosing it with IPMI ISSUE Purpose Why is the red system LED on the front lit? (different than the disk LEDs) Description Newer Unitrends platforms use IPMI firmware to set the red LED if a hardware event occurs. For example: Recovery-712 Recovery-713…
-
Unable to configure hot backup copies due to ping/icmp being unavailable.
ISSUE Hot backup copy configuration fails because the host is not reachable via ICMP/PING when adding a target to a source. RESOLUTION Run this on source to temporarily override the ping check, then attempt setup again. sed -i "s/elif \[ \$ret -eq 1 \]/elif \[ \$ret -eq 100 \]; # Added '`date`' - Workaround for blocked…
-
Capacity report displayed incorrect data when both SQL and Hyper-V roles were enabled on protected Windows servers.
SUMMARY Capacity report displayed incorrect data when both SQL and Hyper-V roles were enabled on protected Windows servers. ISSUE Capacity report displayed incorrect data when both SQL and Hyper-V roles were enabled on single protected Windows server. RESOLUTION To resolve this issue, upgrade your appliance to version…
-
Flashcache block size may be set incorrectly
SUMMARY Flashcache block size may be set incorrectly. ISSUE Flashcache block size may be set to an incorrect value, resulting in sub-optimal utilization of the flash cache. This may cause Recovery Series appliances to underperform in certain scenarios. RESOLUTION To resolve this issue, upgrade your appliance to version…
-
Testing the health of an on-board NIC
SUMMARY Testing the health of an on-board NIC ISSUE Purpose Rule out the on-board NIC on physical systems as the root cause of network problems Description If you’re having problems connecting to clients, one possible cause could be a non-functioning NIC on the physical appliance. Running the command in the Resolution…
-
Cent OS 6 Migration Prerequisites for Physical Appliances
SUMMARY Documentation on what you must have and the tools necessary to perform a Cent OS 6 migration DESCRIPTION Before starting the migration process, check the appliance to make sure it is in a healthy state for the migration to complete successfully. Any critical data that cannot be lost has been archived successfully…
-
Release Notes for Recovery Series and Unitrends Backup 9.1 - Legacy Interface
DESCRIPTION This document describes issues resolved in the 9.1 release for the legacy User Interface (UI). If you are using the current UI, see Release Notes for Recovery Series and Unitrends Backup 9.1. For details about each resolved issue, see Release 9.1.0 Customer Resolved Defects. For complete upgrade instructions…
-
NAS Backup Issues - Domain Password Change
ISSUE If you change the domain password that is associated to all of your clients and NAS clients RESOLUTION If you are using the legacy UI then you will have to go to Settings > Storage and Retention > Storage. Click on the NAS and it will bring up the modify settings, then you will change the password for the new domain…
-
What is the Legacy Administrative Interface? How do I access it in version 9.x and newer?
ISSUE What is the Legacy Administrative Interface? How do I access it in version 9.x and newer? RESOLUTION The Legacy Administrative Interface is real-time web client and interpreter between the Graphical Administrative Interface and the PostgreSQL database. It is based on HTML and Flash converting database queries and…